Model Number |
JERRY-III |
Parameters?? Three parameters??IBP, SPO2, Pulse Rate.
Waveforms: No waveform.
Features?? 1??Compact, light, easy for carrying and handling. 2??Large bright LED display of measurement, easy to read. 3??Unique character and icon display of information, easy for setting and watching. 4??Storage and review of NIBP and SpO2 data up to 800 groups. 5??Build?n rechargeable LI-battery for 10 working hours. 6??Low battery power indicator. 7??Automatic power-off. 8??Audio and visual alarm. 9??External printer available.
Applications?? Handheld patient monitor can be applied in the hospital? operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment.
Standard Packing List?? 1. NIBP??PO2 Patient Monitor main unit 1pc 2. Adult finger SpO2 sensor 1pc 3. Adult NIBP cuff 1pc 4. Child NIBP cuff 1pc 5. NIBP extension tube 1pc 6. AC power adaptor 1pc 7. The operator? manual 1pc
Selectable Accessory?? Child finger/toe SpO2 sensor
Specifications?? 1. General Specifications: Size: 205mm?00mm?5mm Weight: 1 kg Display Specification Parameter Display: 7-segment LEDs Information Display: Fixed characters and icons lighted by single-color LEDs Power Supply Indicator: Dual-color LED 2. Power Supply AC Power Adaptor Input: 100-240VAC, 50/60Hz Output: DC 9V,800mA Battery Lithium-ion rechargeable 5AHr 7.2V battery Operating time: 10 hours with full battery capacity. (Condition: 25°C, NIBP working period is 10 minutes.) Recharge Time: 20 hours. 3. Environment Temperature Working: 0 ~ 45 (°C) Transport and Storage: -25 ~ 85 (°C Humidity Working: 30% - 85 % Transport and Storage: 30% - 95 % (no condensation) 4. Monitoring Parameter NIBP Method: Oscillometric Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min) Measuring Period in STAT Mode: 5 min Cuff Pressure Range: 0 - 300 (mmHg) Pulse Rate Range: 30 - 250 (bpm) Measurement Rage: Adult 30-255mmHg, Pediactri 30-160mmHg Over-pressure Protection: Adult 300mmHg, Pediactri 220mmHg Pressure Resolution: 1mmHg The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using end artery blood pressure measurement device. SpO2 SpO2% Measuring Range: 35 - 99% Resolution: 1 % Accuracy:±2 %(70% - 99%), unspecified (0% - 69%) Pulse Rate Measuring and Alarm Range: 0~250bpm Resolution: 1bpm Accuracy:±1bpm Storage and Review Storage Method: Store NIBP and SPO2 data each time after one NIBP measurement. Maximum Store Data of 800 groups. 5. Printer (optional) Type: Thermal microprinter Record Width:57 mm Recording Types: Real-time printing and review data printing AC Power Adaptor Input: 100-240V,50/60Hz Output: DC 5V, 3A
|